氯化钙干燥剂用杜美纸原纸拉力测试:
测试条件:标距150mm,样宽15mm
取样数 |
最大力值(N) |
平均力值(N) |
断裂伸长率(%) |
1 |
62.92 |
45.91 |
38.229 |
2 |
62.17 |
45.53 |
39.618 |
3 |
52.76 |
39.59 |
30.482 |
4 |
54.85 |
40.60 |
29.561 |
5 |
57.16 |
42.50 |
29.709 |
6 |
63.47 |
46.91 |
34.225 |
7 |
53.79 |
40.18 |
30.173 |
8 |
56.64 |
42.65 |
30.79 |
9 |
59.67 |
43.90 |
34.744 |
10 |
62.44 |
45.89 |
35.314 |
序号 |
取样数 |
热封强度(N) |
① |
1 |
13.25 |
2 |
12.80 |
|
3 |
18.61 |
|
② |
1 |
17.89 |
2 |
17.47 |
|
3 |
12.56 |
|
③ |
1 |
15.12 |
2 |
13.61 |
|
3 |
17.01 |
|
④ |
1 |
16.60 |
2 |
13.68 |
|
3 |
14.30 |
|
⑤ |
1 |
17.79 |
2 |
15.02 |
|
3 |
16.37 |
氯化钙干燥剂用杜美纸纵封热封强度测试:
条件:样宽15mm
序号 |
取样数 |
热封强度(N) |
① |
1 |
7.16 |
2 |
9.23 |
|
3 |
5.84 |
|
② |
1 |
10.80 |
2 |
8.00 |
|
3 |
8.06 |
|
③ |
1 |
8.22 |
2 |
13.91 |
|
3 |
13.50 |
|
④ |
1 |
12.36 |
2 |
15.04 |
|
3 |
14.16 |
|
⑤ |
1 |
14.04 |
2 |
15.09 |
|
3 |